Skip to content

IHLP16012-Each

Inhealth Tech Blom-SingerLow Pressure Voice Prosthesis 16Fr, 12mm L

IHLP16012-Each Inhealth Tech Blom-Singer Low Pressure Voice Prosthesis 16Fr, 12mm L is a silicone one-way flapper valve designed for post-laryngectomy voice restoration. Priced at $50.71, it offers low-pressure airflow for easy phonation and is ideal for patients who need a self-maintainable prosthetic.

$50.71

● In stock

Buy at Diabetesstore.com →

Price and availability may change. Click to see current details on Diabetesstore.com.

Key features

  • Low-pressure silicone valve — opens with minimal airflow for comfortable speech.
  • One-way flapper design — protects the airway while swallowing.
  • 16Fr (12 mm) size — compatible with standard tracheoesophageal puncture kits.
  • Patient-maintainable — can be inserted, removed and cleaned independently.
  • Durable silicone construction — resists bio-film buildup and irritation.
  • Compact profile — fits easily within the prosthetic channel.

Pros

  • +Low pressure enables comfortable speech.
  • +Silicone material reduces irritation.
  • +Self-maintainable without clinician assistance.
  • +Compact 16Fr size fits standard puncture.
!

Cons

  • Requires regular cleaning to prevent blockage.
  • May need periodic replacement after extensive use.
  • Limited to patients able to manage prosthesis themselves.

About IHLP16012-Each Inhealth Tech Blom-SingerLow Pressure Voice Prosthesis 16Fr, 12mm L

What is IHLP16012-Each Inhealth Tech Blom-SingerLow Pressure Voice Prosthesis 16Fr, 12mm L?

The IHLP16012-Each Inhealth Tech Blom-Singer Low Pressure Voice Prosthesis is a medical-grade silicone one-way flapper valve designed for placement between the trachea and esophagus after a total laryngectomy. The 16Fr (12 mm) length fits the standard tracheoesophageal puncture, allowing air to travel from the lungs into the esophagus when the patient exhales, thereby producing voice. Its low-pressure design opens easily, reducing the effort required for phonation while still sealing the airway during swallowing. The valve operates on a simple principle: when positive pressure is generated in the lungs, the silicone flap lifts, allowing a controlled stream of air to pass into the esophagus. When the patient swallows, the flap collapses, preventing reflux of food or liquid into the airway. This dual action supports both speech and safe swallowing.

Key features

  • Low-pressure silicone valve — opens with minimal airflow for comfortable speech.
  • One-way flapper design — protects the airway while swallowing.
  • 16Fr (12 mm) size — compatible with standard tracheoesophageal puncture kits.
  • Patient-maintainable — can be inserted, removed and cleaned independently.
  • Durable silicone construction — resists bio-film buildup and irritation.
  • Compact profile — fits easily within the prosthetic channel.

Who is IHLP16012-Each Inhealth Tech Blom-SingerLow Pressure Voice Prosthesis 16Fr, 12mm L for?

This prosthesis is intended for adults who have undergone a total laryngectomy and require a reliable speech aid. It suits individuals comfortable with self-care, as the device can be removed and cleaned without a clinician. Speech-language pathologists often recommend it for patients who prioritize ease of phonation and airway protection. Patients typically receive training from a speech-language pathologist to master insertion technique, cleaning routine, and optimal speaking strategies. Because the device is reusable, it offers a cost-effective alternative to disposable prostheses, while still meeting the rigorous standards of medical-grade silicone.

How does IHLP16012-Each Inhealth Tech Blom-SingerLow Pressure Voice Prosthesis 16Fr, 12mm L compare?

Compared with higher-pressure prostheses, the low-pressure model delivers softer airflow, which can make the voice sound more natural but may require the speaker to project slightly more effort for louder speech. Unlike Duckbill-style valves, this silicone flapper is generally smoother to clean and less prone to tissue irritation, though it still demands regular maintenance to ensure optimal performance. In practice, clinicians report that the low-pressure design reduces fatigue during prolonged conversations and is especially beneficial for patients who experience discomfort with higher-pressure models. However, users should monitor valve performance and replace the prosthesis according to the manufacturer’s schedule to avoid degradation.

🎯

Best use cases

  • Post-laryngectomy patients seeking voice restoration.
  • Patients preferring a self-cleanable prosthetic.
  • Clinical trials evaluating low-pressure valve performance.
  • Home care settings where clinician visits are infrequent.
🛒

Is Inhealth Tech Blom-SingerLow Pressure Voice Prosthesis 16Fr, 12mm L right for you?

Buy the IHLP16012-Each Inhealth Tech Blom-Singer Low Pressure Voice Prosthesis if you have undergone a total laryngectomy and need a reliable speech aid. It suits users comfortable with inserting and cleaning their own device, offering independence from frequent clinic visits. Beginners should receive initial training from a speech-language pathologist. Alternatives include higher-pressure prostheses for louder voice or standard Duckbill models, but the low-pressure design prioritises ease of phonation and airway protection.

How it compares: Compared with standard high-pressure voice prostheses, the low-pressure IHLP16012-Each model offers gentler airflow for easier speech but may produce a softer voice. It also differs from Duckbill valves by using a silicone flapper, which can be more comfortable and easier to clean, though it still requires regular maintenance.

More from Diabetesstore.com

?

Frequently Asked Questions

What is the purpose of the IHLP16012-Each Inhealth Tech Blom-Singer Low Pressure Voice Prosthesis?

The prosthesis restores speech after a total laryngectomy by allowing air to pass from the trachea into the esophagus through a one-way silicone valve. When the patient exhales, the low-pressure valve opens, creating vibration that produces voice. It also blocks airflow during swallowing, protecting the airway.

Does the prosthesis require professional fitting?

Initial placement of the IHLP16012-Each prosthesis must be performed by a qualified surgeon or otolaryngologist to ensure the tracheoesophageal puncture is correctly sized. After the first insertion, patients can manage removal, cleaning, and reinsertion on their own, but any adjustment or replacement should be overseen by a clinician.

How often should the device be cleaned?

Manufacturers recommend cleaning the prosthesis after each use to prevent biofilm buildup and maintain valve function. A simple rinse with warm water followed by a mild antiseptic solution is sufficient. Some clinicians advise a weekly deep cleaning schedule, especially for patients who speak frequently.

Is the silicone material hypoallergenic?

The prosthesis is made from medical-grade silicone, which is widely regarded as hypoallergenic and biocompatible. While rare allergic reactions can occur, most patients tolerate the material without irritation. If sensitivity is a concern, a physician can perform a patch test before long-term use.

Can the prosthesis be used with standard tracheoesophageal puncture kits?

Yes, the IHLP16012-Each prosthesis conforms to the 16Fr (12 mm) standard size used in most tracheoesophageal puncture kits. It can be inserted with the same introducer tools and retained by the standard flange, making it compatible with existing surgical supplies today.

How much does Inhealth Tech Blom-SingerLow Pressure Voice Prosthesis 16Fr, 12mm L cost?

Inhealth Tech Blom-SingerLow Pressure Voice Prosthesis 16Fr, 12mm L is $50.71 at Diabetesstore.com. Prices may change — click through to Diabetesstore.com for the latest.

Is Inhealth Tech Blom-SingerLow Pressure Voice Prosthesis 16Fr, 12mm L in stock at Diabetesstore.com?

Yes, Inhealth Tech Blom-SingerLow Pressure Voice Prosthesis 16Fr, 12mm L is currently in stock at Diabetesstore.com.

Specifications

Brand
IHLP16012-Each
SKU
79762
Last updated May 14, 2026